engelsk flag   tysk flag   norsk flag   svensk flag   finsk flag australsk flag
exodraft logo
xzense

Xzense

With an Xzense control (in conjunction with an exodraft chimney fan system), you obtain full control of your fireplace and maximum comfort.

No more hassle when lighting and refueling your fireplace. With the click of a button, either on the Xzense itself or on your phone (via the dedicated Xzense app), you get a perfect ”flame picture” in your fireplace. This is regardless of outside temperature, air pressure, wind speed, wind direction and other weather and seasonal factors that influence the chimney draught and thus the workings of the fireplace.

Additional benefits are less smoke spillage, better and cleaner combustion, more efficient fuel economy and faster heating. In other words, Xzense makes sense

  • Full control of your fireplace
  • Touch display
  • Long battery life
Description Xzense
Dimension (H x W x D) 72 x 86 x 25 mm
Weight 120 g
Density class IP20
Voltage 5 V (USB)
Material ABS
Temperature sensor 0 ºC - 40 ºC
Frequency for radiocommunication 868 MHz
Battery type Li-Po Battery
Battery life 30 days (preliminary)
  • Control Xzense
  • Description
  • Technical Specifications
  • Product Range
  • Documentation
EFC15 controller

EFC15

You can manually operate the electronic speed of an exodraft chimney fan with the EFC15 control.

You can turn the chimney fans off and on and adjust the chimney’s draft to the level of your choice.

The speed control is embedded into the on/off switch. When the fan is on, an LED light comes on.

  • Electronic speed regulation
  • Manual operation
Description EFC15
Height (mm) 79
Width (mm) 52
Depth (mm) 57
Max. load 1,5 A
Fuse T 1,6 AH
Voltage 230 V AC, 50 Hz
Ambient temperature 0 ºC – +40 ºC
Density class IP 30
Material ABS
Colour White
  • Control EFC15
  • Description
  • Technical Specifications
  • Product Range
  • Documentation
efc16

EFC16

You can manually operate exodraft chimney fans using the EFC16 electronic speed control in the LK Fuga installation series. The chimney fan motor’s speed can be regulated regularly with the EFC16 control, allowing the chimney fan to be adjusted from 25 to 100%.

As such, you can personalize the chimney fan however you like, whether you are starting a fire, adding fuel to it, or simply want ongoing heat.

  • Electronic speed regulation
  • Manual operation
Description EFC16
Height (mm) 85
Width (mm) 85
Depth (mm) 52
Max. load 1,5 A
Fuse T 1,6 AH
Voltage 230 V AC, 50 Hz
Ambient temperature 0 ºC – +40 ºC
Density class IP 30
Material ABS
Colour White
  • Control EFC16
  • Description
  • Technical Specifications
  • Product Range
  • Documentation
EFC18 controller

EFC18

You can manually control the EFC18 using 9 different speeds with built-in automatic stop/start for the exodraft chimney fan.

The boost function in it comes with allows simpler troubleshooting during ignition and the various settings simplify the lighting settings. It is also easy to refuel, and permits ongoing heating as well.

The EFC18 is equipped with a temperature sensor that can be installed below the chimney fan.

  • Nine unique settings
  • Automatic stop/start
  • Temperature sensor
Description EFC18
Height (mm) 85
Width (mm) 85
Depth (mm) 32,5
Max. load 1,2 A
Fuse T 1,25 AH
Voltage 230 V AC, 50 Hz
Workspace for sensor -50 ºC – +400 ºC
Ambient temperature 0 ºC – +40 ºC
Density class IP 30
Material ABS
Colour White
  • Control EFC18
  • Description
  • Technical Specifications
  • Product Range
  • Documentation
EFC21 controller

EFC21

The control EFC21 was developed for gas fireplaces that are connected to an exodraft chimney fan.

The control monitors the failsafe function and if there is not sufficient chimney draft, the EFC21 stops the gas supply to the fireplace. This is to ensure that no gas enters the room.

When the EFC21 is activated, the chimney fan runs at full speed. If the flowmeter confirms that the chimney draft is sufficient, then the fireplace can be lit and the speed of the chimney fan can be regulated to a pre-set value.

  • Developed for gas fire places
  • Monitors the failsafe function
  • Ensures that no gas enters the room
Description EFC21
Height (mm) 85
Width (mm) 126
Depth (mm) 32
Failsafe pressure control (PDS) 24 V DC (supply for closed circuit)
Fuse 3,15 A T
Voltage 230 V AC, 50 Hz
Chimney fan outlet 1,8 A/230 V (AC 3)
Output, gas solenoid valve (SMG) 230 V AC, max. 100 VA
DIP-switch settings Manuel setting with 3-minute caster
Input, remote on / off button 24 V DC (supply for closed circuit)
Settings for the chimney fan speed Potentiometer on the circuit board
Relay output Max. 3,15 A 250 V AC/3,15 A 30 VDC (Load: 3,15 AT)
Ambient temperature 0 ºC – +40 ºCt
Density class IP 30
Material ABS
Colour White
GASTEC-approval Certifikat-nr.: PIN:0063BT1395
  • Control EFC21
  • Description
  • Video
  • Technical Specifications
  • Product Range
  • Documentation
EFC35 controller

EFC35

The EFC35 is an electronic speed control for exodraft chimney fans that is manually operated.

The chimney fan’s motor speed can be continuously regulated with the EFC35 and its efficiency can be adjusted from 25 – 100%. As such, you can modify your chimney fan to your existing needs, whether you would like to start a fire, add fuel to it, or keep the room heated.

  • On/off switch with LED indicator
  • Manual operation
Description EFC35
Height (mm) 102
Width (mm) 74
Depth (mm) 67
Max. load 3,5 A
Fuse T 4 AH
Voltage 230 V AC, 50 Hz
Ambient temperature 0 ºC – +35 ºC
Density class IP 30
Material ABS
Colour White
  • Control EFC35
  • Description
  • Technical Specifications
  • Product Range
  • Documentation
EBC22_web

EBC22

The EBC22 is an automatic control that comes with a pressure transducer (XTP) for multiple boilers or other installations where numerous heat sources are associated with the same chimney.

With the assistance of the chimney-installed XTP sensor, the low pressure is maintained and monitored by regulating the chimney fan’s speed. There are outputs and inputs on the control for up to two boilers.

You can regulate up to four boilers with the addition of the exodraft ES12 relay box.

  • Pressure transducer
  • XTP sensor
  • For one or more heat sources
Description EBC22
Dimension (H x W x D)t 204 x 240 x 77 mm
Weight 1,62 kg
Density class IP 54
Control range 0 Pa – 150 Pa
Fuse T 4 A
Voltage 230 V AC, 50 Hz
Power consumption 475 W
Settings for the chimney fan speed Potentiometer on the circuit board
Relay output Max. 3,15 A 250 V AC/3,15 A 30 VDC (Load: 3,15 AT)
Ambient temperature -20 ºC – +60 ºC
Material ABS
Colour White
GASTEC-approval Certifikat-nr.: PIN:0063BT1395
  • Control EBC22
  • Description
  • Technical Specifications
  • Product Range
  • Documentation
EBC10-front-medium

EBC10

The EBC10 is an automatic control with a pressure transducer (XTP) for one boiler or other installations with one heat source.

With the help of the XTP sensors, which are installed in the chimney, the low pressure is monitored and maintained by regulating the speed of the chimney fan.

The control has inputs and outputs for one boiler.

  • Pressure transducer
  • XTP sensor
  • For one heat source
Description EBC10
Dimension (H x W x D) 175 x 175 x 100 mm
Weight 1.5 kg
Density class IP 54
Control range 0 Pa – 150 Pa
Fuse 4.0T
Voltage 230 V AC, 50 Hz
Power consumption 475 W
Settings for the chimney fan speed Potentiometer on the circuit board
Relay output Max. 3.15 A 250 V AC/3.15 A 30 VDC (Load: 3.15 AT)
Ambient temperature -20 ºC – +50 ºC
Material ABS
  • Control EBC10
  • Description
  • Technical Specifications
  • Product Range
  • Documentation
EBC24-front-medium

EBC24

The EBC24 is an automatic control that comes with a pressure transducer (XTP) for multiple boilers or other installations where numerous heat sources are associated with the same chimney.

With the assistance of the chimney-installed XTP sensor, the low pressure is maintained and monitored by regulating the chimney fan’s speed. There are outputs and inputs on the control for up to two boilers.

You can regulate up to four boilers with the addition of the exodraft ES12 relay box.

  • Pressure transducer
  • XTP sensor
  • For one or more heat sources
Description EBC24
Dimension (H x W x D) 175 x 175 x 100 mm
Weight 1.5 kg
Density class IP 54
Control range 0 Pa – 150 Pa
Fuse 4.0T
Voltage 230 V AC, 50 Hz
Power consumption 475 W
Settings for the chimney fan speed Potentiometer on the circuit board
Relay output Max. 3.15 A 250 V AC/3.15 A 30 VDC (Load: 3.15 AT)
Ambient temperature -20 ºC – +50 ºC
Material ABS
Colour Transparent cover (indoor) or grey cover (outdoor)
  • Control EBC24EU01 (indoor)
  • Control EBC24EU02 (outdoor)
  • Description
  • Technical Specifications
  • Product Range
  • Documentation
ech20 control

EHC20

The EHC20 is a SMART heat recovery device for your exodraft. If the temperature surpasses the intended water side level, the EHC20’s heat recovery unit opens the secondary flow valve and directs the flue vapor/gas toward the chimney.

As such, overheating is ceased, thereby ensuring safe operation.

The EHC20 also regulates a 3-way mixing valve in order to maintain circulation toward the collection tank, which happens when the water has achieved the intended temperature.

If the water hasn’t reached the intended temperature, the heat exchanger recirculates until the intended temperature is achieved.

  • Intelligent control
  • Overview of your energy savings
  • Quick set-up with the Startup Wizard
Description EHC20
Height (mm) 228
Width (mm) 180
Depth (mm) 53
Display Graphic LCD display, 128 x 128 points
Power consumption 0,5-3 W
Voltage 100-240 V AC, 50-60 Hz
Internal fuse 2 A
Sensor inputs 8 x PT10002 x Grundfos direct sensors 1 x RC21
Workspace, sensors PT1000 -40 – 300 °C Grundfos direct 0 – 100 °C
Network connections Ethernet (optional) CAN bus
Media for reading and writing MicroSD reader
Relay output Max. 3,15 A 250 V AC/3,15 A 30 VDC (Load: 3,15 AT)
Operating temperature 0-40 °C
Storage temperature 0-60 °C
Max. humidity Max. 85% humidity, no condensation
  • Control EFC15
  • Description
  • Technical Specifications
  • Product Range